
axismd.ai
FANUC Controller
Program/G-code · Basic · 10-20 minutes
Fanuc Alarm 301 - RESETTING OF REFERENCE RETURN IS INHIBITED
Alarm 301 indicates a communication failure between the servo amplifier and the absolute pulse coder (APC) on the specified axis. This is typically caused by damaged or disconnected pulse coder cables, faulty connectors, poor shielding/grounding, or a failed absolute encoder battery allowing loss of position data. The CNC cannot receive valid position feedback from the encoder.
Fanuc Alarm 301 - RESETTING OF REFERENCE RETURN IS INHIBITED
RESETTING OF REFERENCE RETURN IS INHIBITED
Fanuc PS301: A reference return reset or re-establishment was attempted but is inhibited by the current machine or parameter configuration.
Root Cause Summary
Alarm 301 indicates a communication failure between the servo amplifier and the absolute pulse coder (APC) on the specified axis. This is typically caused by damaged or disconnected pulse coder cables, faulty connectors, poor shielding/grounding, or a failed absolute encoder battery allowing loss of position data. The CNC cannot receive valid position feedback from the encoder.
Safety
Causes and Fixes
Power off the machine. Inspect the pulse coder cable (typically shielded 9-pin or encoder-specific connector) at both the motor encoder end and the amplifier JD1A/JD1B connector. Check for bent pins, contamination, or looseness.
Ensure LOCK/OFF on the power supply before touching connections
Disconnect and reconnect the pulse coder connector firmly. Check continuity of all signal lines using a multimeter with the cable disconnected from both ends. Verify shield continuity to ground.
If cable damage is suspected, temporarily swap the pulse coder cable with a known good axis (if available) to isolate cable vs. encoder failure. Replace cable if confirmed defective.
After reconnecting, power on and check DIAGNOSIS screen > SERVO > (axis number) for encoder communication status. Monitor diagnostic 300-303 (encoder serial data) for valid changing values during manual movement.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.