Fanuc Alarm 308 - APC ALARM: n AXIS BATTERY DOWN 2
Alarm 308 indicates the absolute pulse coder (APC) battery voltage on the specified axis has reached a critically low level (second warning stage). This is a final warning before absolute position data loss occurs; the battery must be replaced immediately to prevent loss of absolute position reference and potential machine datum issues.
Fanuc Alarm 308 - APC ALARM: n AXIS BATTERY DOWN 2
SERVO ALARM 308
Absolute pulse coder battery voltage is critically low on the n-th axis (second warning level). Replace backup battery immediately.
Root Cause Summary
Alarm 308 indicates the absolute pulse coder (APC) battery voltage on the specified axis has reached a critically low level (second warning stage). This is a final warning before absolute position data loss occurs; the battery must be replaced immediately to prevent loss of absolute position reference and potential machine datum issues.
Causes and Fixes
Check DIAGNOSIS screen > SERVO > APC BATTERY (path varies by series: 0i/16i use SYSTEM > DIAGNOSIS > #300-399, 30i/31i/32i use DIAGNOSIS > SERVO > APC). Record battery voltage values for the affected axis.
Identify the motor serial number and battery type for the affected axis. Replace the APC battery on the motor encoder with correct Fanuc part (BR-2/3A with connector for alpha/beta servo, A98L-0031-0025 for older models). Battery is typically located on motor rear cover.
Battery replacement must be completed within 15-30 minutes of disconnection to prevent loss of absolute position data. Do NOT power down the servo amplifier during replacement.
After battery replacement, clear alarm 308 using RESET key. Verify alarm does not return and check APC battery voltage on DIAGNOSIS screen shows >3.0V DC (normal range 3.2-3.6V).
If alarm persists after battery replacement, perform APC data reset via parameter PWE=1, then SYSTEM > PMC > SETTING > INITIALIZE APC (path varies by control). Re-establish reference position using return-to-zero procedure for the affected axis.
APC reset will erase absolute position data. Machine must be manually homed after this operation.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.