Fanuc Alarm 3001 - Spindle Speed Zero
Fanuc Alarm 3001, Spindle Speed Zero, typically occurs when an M03 or M04 spindle start command is executed without a specified non-zero spindle speed (S word). The most common fix is to ensure a valid S command with a non-zero RPM is programmed before the spindle start command. This is a basic safety interlock issue often resolved by reviewing and editing the CNC program.
Fanuc Alarm 3001 - Spindle Speed Zero
SPINDLE ALARM 3001
Alarm 3001 fires when M03 or M04 is executed but the programmed spindle speed is zero or no S word has been specified. Fanuc requires a valid non-zero speed before allowing spindle rotation. This is a safety interlock — a missing or zero S word is the most common cause.
Root Cause Summary
Fanuc Alarm 3001, Spindle Speed Zero, typically occurs when an M03 or M04 spindle start command is executed without a specified non-zero spindle speed (S word). The most common fix is to ensure a valid S command with a non-zero RPM is programmed before the spindle start command. This is a basic safety interlock issue often resolved by reviewing and editing the CNC program.
Causes and Fixes
Locate Alarm Block
Scroll to the program line where the alarm 3001 was triggered and check for M03 or M04 without an S command in the same or preceding block.
Use the machine's program check function to highlight the active block at the time of the alarm.
Ensure the machine is in a safe state before editing the program.
Add Spindle Speed Command
Edit the program to include an S command with a valid RPM value before the M03 or M04, e.g., insert 'S1200' for 1200 RPM.
Refer to the workpiece material and tool specs to select an appropriate spindle speed.
Avoid excessively high speeds that could damage the tool or workpiece.
Test Run Program
Restart the program in single-block mode to verify the spindle starts correctly with the updated S command and no alarm occurs.
Monitor spindle behavior during the test to ensure smooth operation.
Keep hands clear of moving parts during testing.
Call a technician if:
Prevention
Common Mistakes