FANUC codes
FANUCProgram/G-codeBasic15-30 minutes

300

Fanuc Alarm 300 - ILLEGAL COMMAND IN SCALING

ILLEGAL COMMAND IN SCALING

Fanuc PS300: An illegal command was used while the scaling function (G51) is active. Certain G-codes are not permitted during active coordinate scaling.

Root Cause Summary

Fanuc Alarm 300 - Pneumatic System Fault is typically caused by insufficient air pressure or component failures in the pneumatic system. The most common issue is low air supply pressure due to compressor issues or leaks, which can often be resolved by checking and adjusting the shop air supply or repairing leaks. Regular maintenance of air filters and regulators can prevent recurrence.

Safety

  • Air-operated functions affected

Causes and Fixes

  1. 1

    Check Shop Air Supply

    Locate the main air inlet gauge on the machine and verify the pressure reading. Ensure it is within the manufacturer’s specified range (typically 80-100 PSI).

    If the pressure fluctuates, monitor it over a few minutes to detect compressor cycling issues.

    Ensure the machine is in a safe state before accessing pneumatic components.

  2. 2

    Inspect Compressor Output

    Check the air compressor supplying the shop or machine for proper operation. Listen for unusual noises and verify output pressure matches the system requirements.

    Check the compressor’s duty cycle; continuous running may indicate a leak or capacity issue.

    Avoid direct contact with compressor components while powered.

  3. 3

    Examine Air Dryer and Filters

    Inspect the air dryer and filters upstream of the machine for blockages or saturation. Replace or clean filters if they appear dirty or wet.

    A saturated filter can cause pressure drops; keep spares on hand for quick replacement.

    Depressurize the system before servicing filters to avoid injury.

DIY Feasiblehigh confidence

Call a technician if:

  • ·If compressor failure is confirmed and internal repairs are needed beyond basic troubleshooting.
  • ·If pressure switch or electrical faults persist after basic testing and replacement.

Prevention

  • Schedule regular maintenance for air compressors and filters to ensure consistent pressure.
  • Routinely inspect pneumatic lines and fittings for wear or leaks during downtime.
  • Monitor regulator settings monthly to catch drift before it causes issues.

Common Mistakes

  • Ignoring small air leaks, which can worsen over time and cause pressure loss.
  • Over-tightening fittings during repairs, leading to cracked components or stripped threads.

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.