Okuma OSP codes
Okuma OSPServo/AxisIntermediate

1468

Okuma OSP Alarm A 1468 - Servo amp error XS-axis

Servo amp error XS-axis

The servo controller for the XS-axis (cam axis) has detected an internal fault, commonly a blown fuse in the controller. The cam axis is disabled until the controller is repaired.

Common Causes

  • Blown fuse in the XS-axis (cam-axis) servo controller
  • Faulty XS-axis servo controller unit

Troubleshooting Steps

  1. 1Before opening anything, turn off the main power and lock it out; allow drive capacitors time to discharge before touching the controller.
  2. 2Open the XS-axis servo controller and check its fuse — a blown fuse is the manual's first listed cause; replace it with the same type and rating.
  3. 3If the fuse blows again immediately, the controller unit itself is faulty — replace the unit.
  4. 4The alarm state can be cleared by turning the power off and back on after the repair.
  5. 5If the alarm returns after these checks, record the alarm number and contact Okuma service.

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.