Fanuc Alarm 5139 - FSSB: ERROR
Alarm 5139 indicates a communication failure on the FSSB (Fanuc Serial Servo Bus) network between the CNC and servo amplifiers. This is typically caused by damaged/loose optical fiber cables, amplifier power issues, incorrect FSSB parameter settings (especially parameters 8000-8015 series), or defective optical interface boards on the amplifier or CNC side.
Fanuc Alarm 5139 - FSSB: ERROR
SYSTEM ALARM 5139
Fanuc alarm 5139: SYSTEM ALARM 5139. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Alarm 5139 indicates a communication failure on the FSSB (Fanuc Serial Servo Bus) network between the CNC and servo amplifiers. This is typically caused by damaged/loose optical fiber cables, amplifier power issues, incorrect FSSB parameter settings (especially parameters 8000-8015 series), or defective optical interface boards on the amplifier or CNC side.
Causes and Fixes
Power down CNC and amplifiers. Inspect all optical fiber cables for visible damage, excessive bending, or pinching. Check fiber bend radius is greater than 30mm throughout cable run.
Do not look directly into fiber optic connectors - can cause eye damage from laser diodes
Disconnect and reconnect all FSSB optical fiber connectors at both CNC (JD1A/JD1B) and amplifier ends (CN1/CN2). Clean connector ferrules with lint-free cloth and optical-grade isopropyl alcohol. Ensure positive click when reconnecting.
Check amplifier FSSB LED indicators. Normal operation shows CN1 LED (orange) ON steady and CN2 LED (orange) ON steady for mid-bus amplifiers. First amplifier CN1 only, last amplifier CN2 only. Flashing or OFF indicates communication loss at that point.
If damage found, replace optical fiber cables with FANUC genuine parts (A660-20xx series). Verify FSSB loop topology: CNC JD1A > AMP1 CN1 > AMP1 CN2 > AMP2 CN1... > LAST_AMP CN2 > CNC JD1B forms complete loop.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.