axismd.ai
FANUC Controller
Overtravel/Limit · Intermediate · 30-60 minutes
Fanuc Alarm 514 - INTERFERENCE: +n
Fanuc 514 INTERFERENCE: +n alarm occurs when the rotation area interference check function detects that the programmed tool path or axis movement exceeds the allowable rotation area on the positive side of the specified axis (typically A, B, or C rotary axis). This is a safety interlock preventing collision between the workpiece/fixture and machine components during rotary axis motion.
Fanuc Alarm 514 - INTERFERENCE: +n
SYSTEM ALARM 514
Fanuc alarm 514: SYSTEM ALARM 514. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Fanuc 514 INTERFERENCE: +n alarm occurs when the rotation area interference check function detects that the programmed tool path or axis movement exceeds the allowable rotation area on the positive side of the specified axis (typically A, B, or C rotary axis). This is a safety interlock preventing collision between the workpiece/fixture and machine components during rotary axis motion.
Causes and Fixes
Navigate to SYSTEM > PARAM and check parameters 11310-11319 (rotation area interference check enable/disable for each axis). Verify bit settings for the affected +n axis.
Check parameters 11320-11329 (positive side interference angle) and 11330-11339 (negative side interference angle) for the affected rotary axis. Verify these values match machine mechanical limits and current workpiece setup.
Review parameter 11300 bit settings to confirm rotation area interference check is properly configured (bit 0: check method, bit 1: alarm type). Adjust if interference limits need expansion for current operation.
Increasing interference limits may allow collisions. Verify clearances with dry run at reduced feedrate before production.
If parameters are correct for machine, review part program for excessive rotary axis commands. Check G-code for the +n axis movement that triggered alarm and verify toolpath simulation shows adequate clearance.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.