Fanuc Alarm 515 - INTERFERENCE: -n
Fanuc Alarm 515 INTERFERENCE: -n occurs when the rotational axis interference check function detects that the commanded axis movement would cause a collision or interference on the minus direction of the specified rotary axis (n). This is a software-based collision avoidance alarm triggered by parameters defining interference zones for rotary axes (typically A, B, or C axis).
Fanuc Alarm 515 - INTERFERENCE: -n
SYSTEM ALARM 515
Fanuc alarm 515: SYSTEM ALARM 515. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Fanuc Alarm 515 INTERFERENCE: -n occurs when the rotational axis interference check function detects that the commanded axis movement would cause a collision or interference on the minus direction of the specified rotary axis (n). This is a software-based collision avoidance alarm triggered by parameters defining interference zones for rotary axes (typically A, B, or C axis).
Causes and Fixes
Navigate to SYSTEM > PARAM and check parameters 5500-5549 series. Specifically verify parameters related to rotary axis interference zones (exact parameter depends on axis: A-axis typically uses 5530-5539, B-axis 5540-5544). Note the current minus-side limit settings.
Check parameter 5490 bit settings to verify which interference check function is enabled (bit 0=rotary axis interference check). If bit is ON, the function is active.
Compare the current rotary axis position (visible in POSITION screen - RELATIVE or MACHINE coordinates) against the interference zone parameters. Verify if the commanded move truly violates the mechanical interference zone or if parameters are overly restrictive.
If interference zone parameters are incorrect, adjust parameters 5530-5544 (specific to your rotary axis) to reflect actual mechanical interference boundaries. Record original values before modification. Power cycle the control after parameter changes.
Incorrectly setting interference zones may allow actual collisions. Verify new settings with manual jog mode at reduced feedrate override before automatic operation.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.