Siemens 300864 - Axis drive emergency retraction mode/generator mode not
This alarm occurs when emergency retraction or generator mode is attempted but the drive does not support or is not properly configured for these functions. This typically involves DC link voltage monitoring capabilities and drive-specific settings.
Siemens 300864 - Axis drive emergency retraction mode/generator mode not
Axis drive emergency retraction mode/generator mode not
Emergency retraction/Generator operation is only possible with an active DC link measurement (MD 1161: $MD_FIXED_LINK_VOLTAGE (DC link fixed voltage = 0). In an old hardware version, no DC link measurement is possible and therefore the error message 300765 might appear in addition if MD 1161: $MD_FIXED_LINK_VOLTAGE (DC link fixed voltage) is set to 0 in an old hardware version Control reaction: Interface signals are set. Alarm display.
Root Cause Summary
This alarm occurs when emergency retraction or generator mode is attempted but the drive does not support or is not properly configured for these functions. This typically involves DC link voltage monitoring capabilities and drive-specific settings.
Safety
Causes and Fixes
Check MD 1161 Setting
Access machine data parameters and verify if MD 1161 is set to 0 (active DC link measurement).
Adjust Parameter
If not set to 0, update MD 1161 as per machine manual and save changes.
Reset and Test
Clear the alarm, reset the control, and test the program again.
Call a technician if:
Prevention
Common Mistakes
Related Alarms
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.