Siemens 300900 - Axis drive stop A triggered
The drive is disabled via STOP A. This blocks the pulses over the relay "Antrieb-IMP". Request: In monitoring cycle. If STOP A has been triggered, this can have several reasons: 1. The timer in MD 1356: $MD_SAFE_PULSE_DISABLE_DELAY (delay pulse disable) of STOP B has expired. 2. The speed threshold in MD 1360: $MD_SAFE_STANDSTILL_VELO_TOL (stop speed pulse disable)of STOP B has not been reached. 3. The test of the deactivation path has been requested by the user through SGE "Test stop selection", but the pulses were not deleted in MD 1357: $MD_SAFE_PULSE_DIS_CHECK_TIME (time for testing the pulse disable) when the time stage expired. 4. Safe brake ramp has responded. 5. "SG-specific stop reaction" is set to STOP A and has responded. The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready) Control reaction: Mode group not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.
Siemens 300900 - Axis drive stop A triggered
Axis drive stop A triggered
The drive is disabled via STOP A. This blocks the pulses over the relay "Antrieb-IMP". Request: In monitoring cycle. If STOP A has been triggered, this can have several reasons: 1. The timer in MD 1356: $MD_SAFE_PULSE_DISABLE_DELAY (delay pulse disable) of STOP B has expired. 2. The speed threshold in MD 1360: $MD_SAFE_STANDSTILL_VELO_TOL (stop speed pulse disable)of STOP B has not been reached. 3. The test of the deactivation path has been requested by the user through SGE "Test stop selection", but the pulses were not deleted in MD 1357: $MD_SAFE_PULSE_DIS_CHECK_TIME (time for testing the pulse disable) when the time stage expired. 4. Safe brake ramp has responded. 5. "SG-specific stop reaction" is set to STOP A and has responded. The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready) Control reaction: Mode group not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.
Safety
Common Causes
Troubleshooting Steps
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.