Siemens 300908 - Axis drive stop C triggered

Axis drive stop C triggered

The drive is disabled via STOP C. At the end of the stop reaction, the drive remains under control, the axis is monitored for SBH. Request: In monitoring cycle. If STOP C has been triggered, this can have several reasons (depending on the configuration): 1. The safe speed monitoring has been triggered (MD 1361: $MD_SAFE_VELO_STOP_MODE (SGspecific stop reaction) or MD 1363: $MD_SAFE_VELO_STOP_REACTION (SG-specific stop reaction) (840D as of SW4.2)). 2. The safe end-position monitoring has been triggered (MD 1362: $MD_SAFE_POS_STOP_MODE (safe end position stop reaction)). The alarm indicates the initiation of a "deceleration at current limit" and the internal activation of "safe standstill" Control reaction: NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • The drive is disabled via STOP C.
  • At the end of the stop reaction, the drive remains under control, the axis is monitored for SBH.
  • Request: In monitoring cycle.

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2The user must check the cause and initiate the corresponding measures.
  3. 3Clear alarm with the RESET key. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.