Siemens SINUMERIK Controller
Servo/Axis · Advanced · 30-60 minutes
Siemens 300002 - Axis drive number assigned twice
SIEMENS alarm 300002 Drive Overvoltage occurs when the DC bus voltage in the drive exceeds the maximum threshold defined in parameter P-AXIS-00220 (max voltage limit). This typically results from regenerative braking energy not being properly dissipated or input power supply voltage fluctuations exceeding the drive's tolerance range.
Siemens 300002 - Axis drive number assigned twice
Axis drive number assigned twice
The drive logic number in the NCK MD 13010 DRIVE_LOGIC_NR has been assigned more than once Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.
Root Cause Summary
SIEMENS alarm 300002 Drive Overvoltage occurs when the DC bus voltage in the drive exceeds the maximum threshold defined in parameter P-AXIS-00220 (max voltage limit). This typically results from regenerative braking energy not being properly dissipated or input power supply voltage fluctuations exceeding the drive's tolerance range.
Safety
Causes and Fixes
Check Braking Resistor Status
Navigate to HMI > Diagnostics > Drive > Power Section and verify braking resistor resistance values match parameter P-AXIS-00225 specifications.
Measure actual resistance with multimeter - should be within 10% of rated value
Verify Braking Resistor Power Rating
Check parameter P-AXIS-00226 (braking resistor power) matches installed hardware and application duty cycle requirements.
Undersized braking resistors can overheat and fail, causing drive damage
Adjust Deceleration Ramps
Increase deceleration time in MD32300 (max axis deceleration) to reduce regenerative energy peaks during rapid stops.
Monitor DC bus voltage in real-time via parameter R-AXIS-00210 during test moves
Enable Dynamic Braking Control
Set parameter P-AXIS-00227 (dynamic braking enable) to 1 and adjust P-AXIS-00228 (braking threshold voltage) to activate braking earlier.
Set threshold 50-100V below maximum DC bus voltage limit
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.