Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate20-45 minutes

300003

Siemens 300003 - Axis drive wrong module type

Axis drive wrong module type

The hardware configuration of the drive components established at the time of bus initialization does not correspond to the information in machine data 13030 DRIVE_MODULE_TYPE[p]=. (p. rack location index) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Root Cause Summary

SIEMENS alarm 300003 Drive Undervoltage occurs when the SINAMICS drive's DC link voltage drops below the minimum threshold (typically 80-85% of nominal). This protection mechanism prevents damage to power electronics and ensures proper motor control by monitoring DC bus voltage continuously through internal voltage sensors.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Causes and Fixes

  1. 1

    Check AC Input Voltage

    Navigate to Diagnostics > Drive > Actual Values and verify r0025 (AC line voltage) matches nameplate requirements. Check all three phases for balance within 2%.

    Ensure proper PPE and lockout procedures before measuring line voltage

  2. 2

    Verify Supply Quality

    Use HMI trace function to monitor r0025 over time for voltage sags or fluctuations. Check building electrical supply and transformer tap settings.

    Enable parameter P1080 (supply monitoring) to log voltage variations

  3. 3

    Adjust Undervoltage Threshold

    If supply voltage is consistently low but stable, consider adjusting P1082 (DC link undervoltage threshold) within acceptable limits after consulting drive manual.

    Do not reduce P1082 below manufacturer minimum specifications

DIY Feasiblemedium confidence

Call a technician if:

  • ·Power module replacement required
  • ·DC link capacitor replacement needed
  • ·Persistent alarms after parameter adjustments
  • ·Multiple drives showing same symptoms

Prevention

  • Regular DC link voltage monitoring
  • Scheduled capacitor replacement per service intervals
  • Maintain proper supply voltage quality
  • Optimize motion profiles to reduce regenerative energy

Common Mistakes

  • Ignoring supply voltage quality issues
  • Adjusting P1082 threshold too aggressively
  • Not checking braking resistor specifications
  • Overlooking motor cable condition during troubleshooting