Siemens 21620 - Axis Emergency braking ramp activated
Alarm 21620 fires when the SINAMICS drive loses communication with the motor encoder feedback system, typically due to DRIVE-CLiQ network issues, encoder cable problems, or encoder hardware failure. The drive's safety monitoring detects communication timeouts or signal integrity errors and immediately disables the axis to prevent uncontrolled motion.
Siemens 21620 - Axis Emergency braking ramp activated
Axis Emergency braking ramp activated
The axial emergency braking ramp has been activated for the specified axis/spindle The following causes are possible for activation of the emergency braking ramp: Alarm 26052: Path velocity for auxiliary function output too high Alarm 1012: System error with ID 550006 Alarm 1016: System error with ID 550003, 550005 and 550010 Context-sensitive braking request with priority 13 is active Control reaction: NC Start disable in this channel. Local alarm reaction. The NC switches to follow-up mode. Interface signals are set. Alarm display.
Root Cause Summary
Alarm 21620 fires when the SINAMICS drive loses communication with the motor encoder feedback system, typically due to DRIVE-CLiQ network issues, encoder cable problems, or encoder hardware failure. The drive's safety monitoring detects communication timeouts or signal integrity errors and immediately disables the axis to prevent uncontrolled motion.
Safety
Causes and Fixes
Check DRIVE-CLiQ Cable Connections
Power down system and inspect all DRIVE-CLiQ cable connections from CU320 to motor encoder. Ensure orange DRIVE-CLiQ cables are fully seated and locking tabs engaged.
Always power down before disconnecting DRIVE-CLiQ cables to prevent component damage
Verify Cable Integrity
Check DRIVE-CLiQ cable for physical damage, kinks, or excessive bending near connectors. Measure cable continuity if damage is suspected.
DRIVE-CLiQ cables should not be bent tighter than 10x cable diameter during installation
Test with Known Good Cable
Replace suspected DRIVE-CLiQ cable with known good spare and test axis operation to isolate cable as root cause.
Keep spare DRIVE-CLiQ cables of common lengths in your service kit
Check DRIVE-CLiQ Topology
Access STARTER software, navigate to Project > DRIVE-CLiQ > Topology and verify all encoder components show 'OK' status in the network view.
Red X marks in topology view indicate failed DRIVE-CLiQ components
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.