21619

Siemens 21619 - Block transformation active: motion not possible

Block transformation active: motion not possible

Siemens SINUMERIK alarm 21619: Block transformation active: motion not possible. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

SIEMENS alarm 21619 fires when the SINAMICS drive detects the motor temperature sensor (KTY84 or PTC thermistor) signal is outside the valid resistance range configured in parameter P0601. This occurs due to sensor circuit faults, wiring issues, or actual motor overheating causing the thermistor resistance to exceed the monitoring thresholds defined in P0604-P0606.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Drive Parameter Configuration

    Navigate to SINAMICS Startdrive or HMI Function 'Drive' → 'Parameters' → 'Safety/Monitoring'. Verify P0601 (temperature sensor type) matches installed sensor: 0=none, 1=PTC, 2=KTY84-130, 3=KTY84-150. Check P0604 (min temp) and P0605 (max temp) values are appropriate for sensor type.

    KTY84-130 typically uses P0604=-40°C and P0605=155°C, while PTC sensors use different thresholds

  2. 2

    Measure Sensor Resistance at Motor Terminal Box

    Power down system and LOTO. At motor terminal box, disconnect temperature sensor wires (typically marked T1/T2 or TH1/TH2). Using calibrated multimeter, measure resistance across sensor terminals. KTY84 should read ~1000Ω at 25°C, PTC should read <1500Ω when cold.

    Ensure motor is cool before testing - hot motor will show elevated but valid resistance

  3. 3

    Test Sensor Wiring Continuity

    With sensor disconnected at motor, measure continuity from drive terminal X21 pins (consult drive manual for exact pins) to motor terminal box sensor connections. Resistance should be <5Ω per conductor. Check for shorts between sensor wires and ground/other conductors.

    Use TDR (Time Domain Reflectometer) on long cable runs to locate exact fault position

  4. 4

    Replace Faulty Components

    If sensor reads open/short, replace motor temperature sensor following motor manufacturer procedures. If wiring shows faults, repair/replace temperature sensor cable. After replacement, clear alarm via HMI 'Alarms' → 'Reset' and verify P0604-P0606 parameters show valid temperature readings.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Drive internal hardware fault confirmed
  • ·Motor temperature sensor replacement requires motor disassembly
  • ·Multiple simultaneous temperature alarms across different axes

Prevention

  • Implement regular temperature sensor resistance testing during PM
  • Use proper cable routing and EMI shielding for temperature sensor wiring
  • Monitor r0035 motor temperature trends to identify gradual overheating
  • Maintain motor cooling systems and verify airflow clearances

Common Mistakes

  • Configuring wrong sensor type in P0601
  • Testing sensor resistance on hot motor giving false readings
  • Ignoring gradual temperature rise trends before alarm triggers
  • Routing temperature sensor cables with power cables causing EMI

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.