Siemens SINUMERIK codes
Siemens SINUMERIKSpindleAdvanced30 - 120 minutes

21618

Siemens 21618 - As from block transformation active: overlaid motion too great

As from block transformation active: overlaid motion too great

The share of overlaid motion on the transformation-related axes is so high that the path movement planned by the preparation no longer sufficiently corresponds to the actual ratio for the interpolation. Strategy of singularities, monitoring of working range limitation and dynamic Look Ahead are possibly no longer correct Control reaction: Alarm display.

Root Cause Summary

SINUMERIK alarm 21618 indicates the drive has detected a short circuit between motor phases or from phase to ground. This protection alarm is triggered by the SIMODRIVE power module's internal monitoring circuits when phase current imbalance exceeds safety thresholds.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Power Down and Isolate Drive

    Switch off main power and ensure SIMODRIVE LED shows no power. Remove motor cable from power module X4 connector.

    Always follow LOTO procedures before disconnecting power connections

  2. 2

    Measure Cable Insulation

    Use megohmmeter to test insulation between U-V, V-W, W-U phases at motor cable. Should read >10MΩ minimum.

    Test both at drive end and motor end to isolate fault location

  3. 3

    Inspect Cable Routing

    Check motor cable for pinch points, sharp edges, or damage along cable track. Verify minimum bend radius per Siemens specifications.

    Look for oil contamination which can cause insulation breakdown

  4. 4

    Replace or Reroute Cable

    If insulation fault found, replace motor cable with Siemens approved type. Ensure proper separation from signal cables.

    Use shielded motor cable and connect shield to both drive and motor PE terminals

DIY Feasiblehigh confidence

Call a technician if:

  • ·SIMODRIVE power module replacement required
  • ·Motor winding replacement needed
  • ·Persistent fault after cable/parameter corrections

Prevention

  • Regular motor cable inspection and bend radius compliance
  • Periodic insulation resistance testing
  • Proper motor cable routing away from heat sources
  • Use of appropriate motor cable types per Siemens specifications

Common Mistakes

  • Testing motor insulation while connected to drive
  • Ignoring motor parameter verification
  • Not checking cable shield grounding
  • Assuming alarm is always hardware fault without checking parameters