Siemens 21615 - Axis taken from traverse mode to follow-up mode

Axis taken from traverse mode to follow-up mode

This axis has been taken from traverse mode and put into "Follow-up" mode, for instance because the pulse enable for the drive has been reset Control reaction: NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Root Cause Summary

SIEMENS alarm 21615 fires when the SINAMICS drive DC bus voltage drops below the threshold defined in MD36300 (motor module) or MD36200 (infeed module). This typically occurs due to incoming power supply issues, regenerative braking overload, or drive hardware faults affecting the rectifier or DC bus capacitors.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Line Voltage at Drive Input

    Navigate to HMI > Diagnostics > Drive > Actual Values and verify input voltage L1-L2-L3. Compare against nameplate rating and MD32000 (nominal line voltage).

    Use SINAMICS Startdrive to monitor real-time voltage values during alarm occurrence

  2. 2

    Verify Power Supply Stability

    Check facility power quality with oscilloscope at drive input terminals. Look for voltage sags, harmonics, or phase imbalance affecting rectifier operation.

    Measure with drive powered - use proper PPE and lockout procedures

  3. 3

    Review Drive Parameters

    Access Parameter > Drive > Power Supply and verify MD32000 matches actual supply voltage. Check MD36200 (infeed undervoltage threshold) is appropriate for application.

    MD36200 default is typically 85% of nominal DC bus voltage

DIY Feasiblehigh confidence

Call a technician if:

  • ·DC bus capacitor replacement required
  • ·Rectifier module hardware failure confirmed
  • ·Persistent alarms after parameter corrections

Prevention

  • Monitor DC bus voltage trends via r0026
  • Schedule preventive capacitor replacement every 5-7 years
  • Maintain proper drive cooling and ambient temperature
  • Use line reactors to improve power quality

Common Mistakes

  • Ignoring power quality issues at facility level
  • Incorrect MD36200/MD36300 threshold settings
  • Operating with degraded cooling system
  • Oversized braking resistor parameters causing nuisance trips

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.