Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 30-60 minutes
Siemens 300004 - Axis drive wrong drive type (FDD/MSD)
SINUMERIK alarm 300004 Drive Overtemperature occurs when the drive module's internal temperature exceeds the threshold defined in MD1400 (temperature monitoring parameters). This typically results from inadequate cooling, excessive load conditions, or drive hardware degradation affecting thermal management.
Siemens 300004 - Axis drive wrong drive type (FDD/MSD)
Axis drive wrong drive type (FDD/MSD)
A feed module is inserted in the rack location determined by the drive logic number, but in the corresponding NCK-specific MD 13040 DRIVE_TYPE, a main spindle is defined (or vice versa) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.
Root Cause Summary
SINUMERIK alarm 300004 Drive Overtemperature occurs when the drive module's internal temperature exceeds the threshold defined in MD1400 (temperature monitoring parameters). This typically results from inadequate cooling, excessive load conditions, or drive hardware degradation affecting thermal management.
Safety
Causes and Fixes
Check Drive Cabinet Cooling
Navigate to HMI > Diagnostics > Drive > Temperature Display to verify current drive temperatures against MD1400 limits.
Normal operating temperature should be 20-30°C below the alarm threshold
Inspect Cooling Fans
Physically inspect all cabinet cooling fans for operation. Check fan status in Service > Drive > Hardware Status menu.
Ensure cabinet power is locked out before accessing internal components
Clean Heat Exchangers
Remove accumulated debris from drive heat sinks and air filters. Check air flow paths are unobstructed.
Use compressed air at low pressure to avoid damaging sensitive components
Verify Ambient Temperature
Ensure cabinet ambient temperature is within specification (typically <40°C). Check MD1402 for ambient temperature monitoring if equipped.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.