Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 30-120 minutes
Siemens 300007 - Axis drive not present or inactive
This alarm occurs when the axis-specific machine data references a drive logic number that does not exist or is inactive. Correct the machine data settings for the affected axis to resolve it.
Siemens 300007 - Axis drive not present or inactive
Axis drive not present or inactive
In the axis-specific machine data 30110 CTRLOUT_MODULE_NR (this specifies at which drive module the speed setpoint is output) and MD 30220 ENC_MODULE_NR (this specifies the drive module which outputs the encoder actual value for the position control) there is a drive logic number that does not occur in the NCK MD 13010 DRIVE_LOGIC_NR and the machine data 30240 ENC_TYPE and MD 30130 CTRLOUT_TYPE are set to "1" Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.
Root Cause Summary
This alarm occurs when the axis-specific machine data references a drive logic number that does not exist or is inactive. Correct the machine data settings for the affected axis to resolve it.
Safety
Causes and Fixes
Identify Affected Axis
Note the axis and drive number mentioned in the alarm message.
Check Machine Data
Access MD 30110 and MD 30220 for the specified axis and verify the drive logic numbers.
Correct Settings
Update the machine data to reference a valid drive module number and save changes.
Reset and Test
Clear the alarm, reset the control, and test the axis operation.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?