Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

300006

Siemens 840D 300006 - Module with drive number has not been found on drive bus

Module with drive number has not been found on drive bus

Siemens SINAMICS drive alarm 300006: Module with drive number has not been found on drive bus. This alarm indicates a fault condition in the SINAMICS servo drive system. Refer to the Siemens SINAMICS fault list documentation for the complete remedy.

Root Cause Summary

This alarm occurs when a drive module specified in MD $MN_DRIVE_LOGIC_NR is not detected on the drive bus, often due to configuration errors or missing hardware. Fix by verifying the configuration or physical connections.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    SAFETY: Power down and lockout

    Follow LOTO procedures before accessing any configuration or hardware. Ensure all energy sources are isolated.

  2. 2

    Check machine data

    Access MD $MN_DRIVE_LOGIC_NR via the configuration display to identify the listed drive number. Create backup of current configuration before making changes.

  3. 3

    Verify drive presence

    With power isolated, confirm if the specified drive module is physically connected to the drive bus.

  4. 4

    Update configuration

    Correct the machine data to match the actual drive setup or reconnect the missing module. Verify changes before powering up.

Service Recommendedmedium confidence

Call a technician if:

  • ·If not qualified in Siemens drive configuration
  • ·If the drive module is connected but not detected
  • ·If machine data corrections do not resolve the alarm
  • ·If unsure about LOTO procedures

Prevention

  • Validate drive configuration during setup
  • Document physical drive layout for reference

Common Mistakes

  • Overlooking unconnected drive modules
  • Incorrectly editing machine data without backup
  • Working on live systems without proper LOTO
  • Not following ESD precautions when handling drive modules

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.