Siemens 25010 - Axis pollution of measuring system
SINUMERIK alarm 25010 occurs when the axis reference point search fails to detect the encoder's zero mark pulse within the configured search distance or timeout period. This prevents the control from establishing absolute position reference, blocking automatic operation until proper homing is achieved.
Siemens 25010 - Axis pollution of measuring system
Axis pollution of measuring system
Siemens SINUMERIK alarm 25010: Axis pollution of measuring system. Detailed remedy is being verified against the current Siemens diagnostics manual.
Root Cause Summary
SINUMERIK alarm 25010 occurs when the axis reference point search fails to detect the encoder's zero mark pulse within the configured search distance or timeout period. This prevents the control from establishing absolute position reference, blocking automatic operation until proper homing is achieved.
Safety
Causes and Fixes
Check Encoder Reference Signal
Navigate to Diagnostics > Drive > Encoder and monitor the reference mark signal (R signal) while manually moving the axis through the expected reference position.
Use oscilloscope on encoder R+ and R- terminals to verify 11µApp signal amplitude
Verify Encoder Power Supply
Check encoder supply voltage at terminals 467/468 on drive unit - should be 5VDC ±5% for incremental encoders or 8-30VDC for absolute encoders.
Disconnect drive power before measuring encoder supply voltages
Inspect Encoder Mechanical Condition
Remove encoder cover and inspect code disk for cracks, contamination, or misalignment. Clean with lint-free cloth and isopropyl alcohol if contaminated.
Look for oil film on glass disk - common cause of intermittent reference mark detection
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.