Siemens 25010 - Axis pollution of measuring system

Axis pollution of measuring system

Siemens SINUMERIK alarm 25010: Axis pollution of measuring system. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

SINUMERIK alarm 25010 occurs when the axis reference point search fails to detect the encoder's zero mark pulse within the configured search distance or timeout period. This prevents the control from establishing absolute position reference, blocking automatic operation until proper homing is achieved.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Causes and Fixes

  1. 1

    Check Encoder Reference Signal

    Navigate to Diagnostics > Drive > Encoder and monitor the reference mark signal (R signal) while manually moving the axis through the expected reference position.

    Use oscilloscope on encoder R+ and R- terminals to verify 11µApp signal amplitude

  2. 2

    Verify Encoder Power Supply

    Check encoder supply voltage at terminals 467/468 on drive unit - should be 5VDC ±5% for incremental encoders or 8-30VDC for absolute encoders.

    Disconnect drive power before measuring encoder supply voltages

  3. 3

    Inspect Encoder Mechanical Condition

    Remove encoder cover and inspect code disk for cracks, contamination, or misalignment. Clean with lint-free cloth and isopropyl alcohol if contaminated.

    Look for oil film on glass disk - common cause of intermittent reference mark detection

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder replacement required
  • ·Drive module encoder interface failure
  • ·Complex parameter optimization needed

Prevention

  • Regular encoder cleaning and inspection
  • Proper cable routing away from power lines
  • Periodic verification of reference point parameters
  • Maintain proper encoder coupling condition

Common Mistakes

  • Ignoring encoder cable shield grounding
  • Setting reference search distance too small
  • Not checking encoder supply voltage first
  • Forcing reference point search with mechanical obstructions present

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.