Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30 minutes - 4 hours

25030

Siemens 25030 - Axis actual velocity alarm limit

Axis actual velocity alarm limit

Siemens SINUMERIK alarm 25030: Axis actual velocity alarm limit. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

SIEMENS alarm 25030 fires when the drive's position controller detects insufficient motor movement despite commanded torque output, typically due to mechanical binding, encoder feedback issues, or motor/drive power stage failures. The SINUMERIK system monitors the deviation between MD32200 (position setpoint) and encoder actual position, triggering this alarm when the lag error exceeds MD32410 thresholds.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Mechanical Binding

    Navigate to Diagnostics > Drive Status and verify actual current vs. commanded current. Manually check axis movement with drive disabled via HMI Service > Drive > Manual Operation.

    Ensure machine is in safe state and emergency stop is accessible before manual movement

  2. 2

    Verify Load Parameters

    Check MD32910 (rated motor current) and MD32920 (maximum motor current) settings against actual load requirements in Parameters > Machine Data > Drives.

    Compare current consumption during normal operation - should be 20-40% of rated current for typical positioning moves

  3. 3

    Inspect Coupling and Transmission

    Examine mechanical coupling between motor and load for wear, backlash, or failure. Check belt tension, gear mesh, and ballscrew condition.

    Listen for unusual noise during movement - grinding indicates mechanical wear

DIY Feasiblehigh confidence

Call a technician if:

  • ·Drive hardware replacement required
  • ·Complex mechanical repairs needed
  • ·Parameter optimization beyond basic settings

Prevention

  • Regular mechanical maintenance and lubrication
  • Periodic encoder cable inspection
  • Monitor drive current consumption trends
  • Maintain proper ambient temperature for drive electronics

Common Mistakes

  • Ignoring mechanical binding and focusing only on electrical issues
  • Adjusting following error limits without addressing root cause
  • Replacing drives without checking motor and encoder first
  • Incorrect motor parameter entry during commissioning

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.