Siemens 840D 101112 - No drives configured !

No drives configured !

Siemens SINUMERIK message 101112: No drives configured!. This is an operator information message from the SINUMERIK control. Note the complete message text as it may contain important parameter values.

Root Cause Summary

Alarm 101112 occurs when the SINUMERIK 840D system attempts to enter Service Drive mode but finds no drive configuration data in the NCK. This typically indicates an incomplete or corrupted startup process where drive configuration parameters were not properly loaded or saved during commissioning.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Boot the control into HMI and verify the current startup level by checking machine data MD11210 (STARTUP_MODE_MASK).

  2. 2

    Access HMI Commissioning mode and navigate to the drive configuration section under 'Startup' -> 'Drives'.

  3. 3

    Configure all required drives by setting drive type, interface parameters (PROFIBUS/PROFINET address), and assign drives to axes in machine data MD30110 to MD30130.

    Incorrect drive configuration can cause physical damage. Verify motor and drive compatibility before proceeding.

  4. 4

    Complete the startup sequence by executing 'Power On' with complete data save, then perform a full NCK reset (power cycle recommended).

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.