Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

101132

Siemens 840D 101132 - Impermissible value execution argument

Impermissible value execution argument

Siemens SINUMERIK operator message 101132: Impermissible value execution argument. This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.

Root Cause Summary

Alarm 101132 occurs when the NC program contains an invalid or out-of-range value for an execution argument in a command or function call. This typically happens with incorrect parameters in system functions, subroutine calls, or technology functions where the value violates defined limits or data type requirements.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Identify the exact block number from the alarm detail where execution stopped and review the NC program line.

  2. 2

    Check all function parameters against Siemens documentation for that specific system function to verify value ranges and data types.

  3. 3

    Verify that R-parameters or variables used as arguments contain valid values by checking their assignment in previous program blocks.

  4. 4

    Correct the parameter value or variable assignment to fall within permissible range and retest the program.

    Backup the original program before making modifications.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.