Siemens SINUMERIK Controller
Parameter · Intermediate · 10-30 minutes
Siemens 1005 - Operating system error parameter
SINUMERIK alarm 1005 fires when the mode group (BAG) cannot establish or maintain the necessary preconditions for operation, typically due to PLC interface signal failures, drive system faults, or invalid NCK configuration data. The mode group requires all associated axes and channels to be ready before allowing transitions between JOG, MDA, and AUTO operating modes.
Siemens 1005 - Operating system error parameter
Operating system error parameter
This alarm indicates that the operating system has detected a serious error Control reaction: NC not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.
Root Cause Summary
SINUMERIK alarm 1005 fires when the mode group (BAG) cannot establish or maintain the necessary preconditions for operation, typically due to PLC interface signal failures, drive system faults, or invalid NCK configuration data. The mode group requires all associated axes and channels to be ready before allowing transitions between JOG, MDA, and AUTO operating modes.
Safety
Causes and Fixes
Check PLC Interface Status
Navigate to Diagnostics > PLC > Interface Signals and verify DB21 (NCK to PLC) and DB20 (PLC to NCK) signal states are correct.
Use the PLC diagnostics screen to monitor real-time signal changes during mode transitions.
Verify NC_START Signal
Check that DB21.DBX1.0 (NC_START) is set to 1 by the PLC program. This signal must be active for mode group initialization.
Never force PLC signals without understanding the safety implications in your specific application.
Examine PLC Program Logic
Review the PLC program for conditions that may prevent setting the NC interface signals, particularly safety interlocks and mode selection logic.
Reset PLC Interface
Perform a PLC reset via Services > PLC > Reset to reinitialize the interface communication between NCK and PLC.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?