Siemens SINUMERIK codes
Siemens SINUMERIKParameterIntermediate10-30 minutes

1005

Siemens 1005 - Operating system error parameter

Operating system error parameter

This alarm indicates that the operating system has detected a serious error Control reaction: NC not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Root Cause Summary

SINUMERIK alarm 1005 fires when the mode group (BAG) cannot establish or maintain the necessary preconditions for operation, typically due to PLC interface signal failures, drive system faults, or invalid NCK configuration data. The mode group requires all associated axes and channels to be ready before allowing transitions between JOG, MDA, and AUTO operating modes.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check PLC Interface Status

    Navigate to Diagnostics > PLC > Interface Signals and verify DB21 (NCK to PLC) and DB20 (PLC to NCK) signal states are correct.

    Use the PLC diagnostics screen to monitor real-time signal changes during mode transitions.

  2. 2

    Verify NC_START Signal

    Check that DB21.DBX1.0 (NC_START) is set to 1 by the PLC program. This signal must be active for mode group initialization.

    Never force PLC signals without understanding the safety implications in your specific application.

  3. 3

    Examine PLC Program Logic

    Review the PLC program for conditions that may prevent setting the NC interface signals, particularly safety interlocks and mode selection logic.

  4. 4

    Reset PLC Interface

    Perform a PLC reset via Services > PLC > Reset to reinitialize the interface communication between NCK and PLC.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Drive hardware replacement needed
  • ·Safety system reconfiguration required
  • ·NCK hardware failure suspected

Prevention

  • Regularly backup machine data and PLC programs
  • Monitor drive status during preventive maintenance
  • Keep safety system documentation current
  • Perform periodic PLC interface signal verification

Common Mistakes

  • Forcing PLC signals without understanding safety implications
  • Ignoring drive communication errors
  • Modifying machine data without proper backup
  • Bypassing safety interlocks during troubleshooting