Siemens SINUMERIK codes
Siemens SINUMERIKSystemBasic5-15 minutes

1001

Siemens 1001 - System error

System error

With this alarm, internal alarm states are displayed that, in conjunction with the transferred error number, provide information on the cause and location of the error Control reaction: Mode group not ready. Channel not ready. Interface signals are set. Alarm display.

Root Cause Summary

SIEMENS alarm 1001 indicates that a Safety Integrated function has been triggered, placing axes into a safe monitored state (STO, SS1, SLS, etc.). The alarm serves as a supervisory flag while the actual safety violation is detailed in companion 60xxxx NCK safety or 20xxxx/30xxxx SINAMICS safety alarms.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Physical Safety Devices

    Verify all E-stop buttons are released and safety doors/guards are properly closed and latched.

    Never bypass safety devices - ensure all personnel are clear before reset

  2. 2

    Examine Safety Chain Status

    Navigate to Diagnostics > Drive > Safety and check F-DI status for safety inputs SI_0 through SI_5 on each SINAMICS drive unit.

    Green indicators show active safety inputs - all should be green for normal operation

  3. 3

    Reset Safety System

    Press machine RESET button, then execute safety acknowledgment via HMI Safety menu or MD36010 (SAFE_ACKNOWLEDGE) parameter reset.

    Some systems require holding RESET for 3+ seconds for proper safety chain reset

  4. 4

    Verify Drive Ready Status

    Check SINAMICS r0899.31 (Safety function active) bit is cleared and r0002.0 (Drive ready) is set before attempting axis movement.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Safety parameter corruption requiring reconfiguration
  • ·Persistent PROFIsafe communication failures
  • ·Multiple simultaneous safety violations

Prevention

  • Regular safety system testing per machine documentation
  • Proper work offset verification before program execution
  • Maintain clean and secure safety device connections
  • Monitor safety parameter backup integrity

Common Mistakes

  • Bypassing safety devices instead of proper troubleshooting
  • Modifying safety speed/position limits without proper authorization
  • Ignoring companion safety alarms that identify root cause
  • Attempting to reset safety system without clearing underlying fault condition

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.