Siemens 840D 100106 - Error on saving

Error on saving

This message will be displayed on editing a file (part program), if a memory operation could not be performed correctly.

Root Cause Summary

SIEMENS alarm 100106 occurs when the SINUMERIK control cannot complete a memory write operation during part program editing or file operations. This typically indicates insufficient memory space, file system corruption, or hardware issues with the CF card or internal storage.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check memory status via HMI

    Navigate to Diagnostics > Service > Memory and check available space on CF card and internal memory. Minimum 10% free space required.

    Use machine data MD11210 $MN_MEMCARD_MEMORY_SIZE to verify CF card capacity

  2. 2

    Delete unnecessary files

    Access Program Manager > WorkPieces and delete old part programs, backup files (.BAK), and temporary files (.TMP) to free up space.

    Always backup critical programs before deletion

  3. 3

    Archive programs to external storage

    Use Data In/Out function to transfer older programs to USB or network drive, then remove from CF card.

    Set up automatic archiving using MD20734 $MC_ARCHIVE_MEMORY_LIMIT

  4. 4

    Verify memory allocation

    Check MD11200 $MN_MEMCARD_ENABLE and MD11220 $MN_MEMCARD_PART_PROG_MEM settings to ensure proper memory allocation for part programs.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Memory hardware tests fail
  • ·Multiple CF card replacements don't resolve issue
  • ·NCU hardware errors persist after basic troubleshooting

Prevention

  • Maintain 15% free space on CF card
  • Regular backup of critical programs
  • Use industrial-grade CF cards only
  • Monitor system temperatures
  • Implement automatic program archiving

Common Mistakes

  • Editing programs during machining operations
  • Ignoring low memory warnings
  • Using consumer-grade CF cards
  • Not backing up before file system repairs
  • Attempting to save oversized programs