Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100110

Siemens 840D 100110 - Read access not allowed in this state

Read access not allowed in this state

Siemens SINUMERIK alarm 100110: Read access not allowed in this state. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

SIEMENS alarm 100110 occurs when the system attempts to read servo drive parameters or data while the drive is in an incompatible operational state. This typically happens during active motion, drive initialization sequences, or when the servo is in a fault condition that prevents parameter access.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check drive operating state

    Navigate to Diagnostics > Drive > Status and verify the current drive state. Look for RUN, ACTIVE, or motion-in-progress indicators.

    Use DB31 DBX60.0 (servo enable) and DB31 DBX60.1 (drive ready) to verify exact drive status

  2. 2

    Stop active motion

    Execute M00 program stop or press NC STOP to halt all axis movement. Wait for drives to reach STANDBY state.

    Ensure workpiece and tooling are in safe position before stopping motion

  3. 3

    Retry parameter access

    Access Commissioning > Drive > Parameters or use SINAMICS Startdrive to read the required parameters once drives are in STANDBY state.

  4. 4

    Verify parameter access rights

    Check machine data MD30240 (DRIVE_PARAMETER_ACCESS_LEVEL) to ensure sufficient access level for the parameter being read.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Drive hardware faults persist after clearing
  • ·Safety system configuration issues
  • ·Firmware compatibility problems

Prevention

  • Always stop motion before accessing drive parameters
  • Maintain proper user access level management
  • Monitor drive status before parameter operations
  • Keep SINAMICS firmware updated

Common Mistakes

  • Attempting parameter access during active machining
  • Ignoring drive fault conditions
  • Using insufficient access level
  • Not waiting for commissioning completion

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.