Siemens 1000 - System error

System error

With this alarm, internal alarm states are displayed that, in conjunction with the transferred error number, provide information on the cause and location of the error Control reaction: NC not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Root Cause Summary

SINUMERIK Alarm 1000 occurs when the NC kernel fails to complete its boot sequence and cannot establish communication with critical system components. This typically results from hardware initialization failures, corrupted system files, or safety circuit interruptions that prevent the control from reaching operational ready state.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Boot Diagnostics

    Access HMI Diagnostics → System Data → Boot Messages to review NCK startup log for file system errors or missing components.

    Look specifically for 'NCK_BOOT.INI' and system partition errors in the boot log

  2. 2

    Verify CompactFlash Integrity

    Navigate to Commissioning → System → Memory Card and run file system check. Replace CompactFlash if bad sectors detected.

    Always power down system completely before removing CompactFlash card

  3. 3

    Restore System Backup

    Load known good system backup via Commissioning → Backup/Restore → Complete Backup to restore corrupted NCK files.

    Keep multiple dated backups - corruption can occur gradually over time

  4. 4

    Perform Cold Restart

    Execute complete system cold start via HMI: Diagnostics → Control → Cold Restart to reinitialize all NCK components.

    Cold restart will clear all temporary data and require axis reference

DIY Feasiblemedium confidence

Call a technician if:

  • ·Hardware component failures detected
  • ·Safety system modifications required
  • ·Multiple system backups fail to resolve issue
  • ·Drive communication cannot be restored

Prevention

  • Maintain regular system backups including NCK and safety data
  • Monitor CompactFlash health and replace proactively
  • Keep spare licensed CompactFlash cards available
  • Implement UPS protection to prevent power-related corruption

Common Mistakes

  • Attempting to modify safety parameters without proper authorization
  • Ignoring gradual boot time increases indicating storage degradation
  • Not verifying license validity after hardware changes
  • Performing warm restarts when cold restart is required for full initialization

Seeing Multiple Alarms?