Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100002

Siemens 840D 100002 - MS DOS test version !

MS DOS test version !

Siemens SINUMERIK operator message 100002: MS DOS test version!. This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.

Root Cause Summary

SIEMENS alarm 100002 'MS DOS test version !' indicates the SINUMERIK system has detected an incompatible or test version of MS DOS running on the PCU (PC Unit). This typically occurs when the system boots from incorrect media or has corrupted system files that revert to a test/development version of the operating system.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Power down and inspect boot media

    Shut down the SINUMERIK system properly and remove the CompactFlash card from the PCU. Inspect for physical damage or corrosion on contacts.

    Always follow proper shutdown procedures via HMI before removing power

  2. 2

    Verify CompactFlash integrity

    Insert CompactFlash into a card reader and scan for file system errors. Check if SINUMERIK system files are present in correct directory structure.

    Look for the presence of \addon\sinumerik directory structure to confirm proper SINUMERIK installation

  3. 3

    Restore from backup or replace media

    If corrupted, restore from known good backup CompactFlash or create new system media using SINUMERIK System Recovery tools.

    Always maintain current backup of working CompactFlash configuration

DIY Feasiblehigh confidence

Call a technician if:

  • ·PCU hardware replacement required
  • ·SINUMERIK license issues during reinstallation
  • ·Persistent alarm after all troubleshooting steps

Prevention

  • Maintain current CompactFlash backups
  • Use only authorized SINUMERIK software versions
  • Implement regular system health checks
  • Protect PCU from power fluctuations with UPS

Common Mistakes

  • Using consumer-grade CompactFlash instead of industrial grade
  • Attempting to boot SINUMERIK from network without proper configuration
  • Mixing SINUMERIK software versions during updates

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.