Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisAdvanced30-120 minutes

25000

Siemens Alarm 25000 - Hardware Fault of Active Encoder

Encoder Hardware Fault

This alarm indicates the CNC control has detected corrupted or missing signals from the position feedback encoder on an active axis. The control system continuously monitors encoder signal quality and triggers this fault when it cannot reliably determine axis position due to signal degradation, loss of quadrature relationship, or complete signal dropout.

Root Cause Summary

SIEMENS alarm 25000 fires when the SINUMERIK control detects corrupted, missing, or invalid encoder feedback signals that prevent reliable position determination. The control continuously monitors encoder signal integrity through the DRIVE-CLiQ interface and triggers this fault when quadrature signals are lost, contaminated, or fall outside acceptable voltage thresholds.

Safety

  • Axis must be re-referenced after clearing
  • Position data is unreliable
  • Disconnect power to the CNC machine before working on any electrical components.
  • Be careful when working near moving parts. Ensure the axis is locked or disabled before performing any maintenance.
  • Use proper grounding techniques when working with electrical connections to prevent electrical shock.
  • Refer to the CNC machine's safety manual for specific safety precautions.
  • High voltages may be present in the CNC control cabinet. Only qualified personnel should work inside the cabinet.
  • Ensure the axis is properly supported before disconnecting the encoder to prevent uncontrolled movement due to gravity.
  • Be aware of potential pinch points when working around moving axes.
  • Always power down and follow lockout/tagout procedures before physical inspections

Causes and Fixes

  1. 1

    Check DRIVE-CLiQ Connection Status

    Navigate to Diagnostics > Hardware > DRIVE-CLiQ and verify all encoder connections show 'OK' status. Check for yellow/red indicators on affected axis.

    Use the DRIVE-CLiQ topology view to identify exactly which connection segment is failing.

  2. 2

    Inspect Encoder Cable Routing

    Examine encoder cable for damage, especially at cable carriers and entry points. Check separation from power cables (minimum 10cm for unshielded).

    Always power down before disconnecting encoder cables to prevent damage to DRIVE-CLiQ interface.

  3. 3

    Verify Cable Continuity

    With system powered down, use multimeter to check continuity on encoder cable pins. Verify shield connection and measure insulation resistance (>10MΩ).

    SINUMERIK encoder cables typically use 15-pin D-sub or M23 connectors - check pinout in drive documentation.

  4. 4

    Test with Spare Cable

    If available, temporarily replace encoder cable with known good spare and clear alarm using NC Reset. Monitor for alarm recurrence during axis movement.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder replacement required
  • ·Drive module hardware failure confirmed
  • ·Multiple axes affected simultaneously
  • ·Safety-critical axis involved

Prevention

  • Regular encoder cable inspection during PM
  • Maintain proper cable routing away from power cables
  • Monitor encoder signal quality trends
  • Keep spare encoder cables in stock
  • Document working encoder parameters

Common Mistakes

  • Swapping encoder cables between axes without parameter changes
  • Ignoring intermittent alarms until complete failure
  • Not checking cable shield grounding
  • Assuming encoder fault when drive hardware is failing
  • Modifying encoder parameters without understanding signal requirements

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.