Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100570

Siemens 840D 100570 - Error TA: not found

Error TA: not found

Siemens SINUMERIK alarm 100570: Error TA: not found. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

SIEMENS alarm 100570 'Error TA: %1 not found' occurs when the SINUMERIK system cannot locate a specified tool adapter (TA) definition in the tool management data. This typically happens when the tool adapter referenced in the NC program or tool data doesn't exist in the tool adapter table or has been incorrectly defined.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Tool Management

    Navigate to HMI → Machine → Tool Management → Tool Adapters to verify if the referenced TA exists in the system database.

  2. 2

    Check TA Number Range

    Verify the TA number falls within the configured range defined in machine data MD18118 (MM_NUM_TOOL_ADAPTER) and MD18119 (MM_TOOL_ADAPTER_PRESEL).

    SINUMERIK systems typically support TA numbers 1-9999, but your machine configuration may limit this range.

  3. 3

    Create Missing TA Entry

    If TA is missing, create new tool adapter entry with correct geometry data including length offset, radius compensation, and orientation parameters.

    Ensure machine is in safe position before modifying tool adapter data.

  4. 4

    Verify TA Parameters

    Check that all mandatory TA parameters are populated including $TA_DP1 through $TA_DP6 geometry values and $TA_TYPE adapter type definition.

DIY Feasiblehigh confidence

Call a technician if:

  • ·System file corruption detected
  • ·Machine data changes required beyond operator level
  • ·Database corruption cannot be resolved with standard procedures

Prevention

  • Regular backup of tool management data
  • Validate TA references before running new NC programs
  • Monitor tool adapter database integrity during routine maintenance

Common Mistakes

  • Assuming TA numbers are automatically sequential
  • Not backing up tool data before making changes
  • Confusing tool numbers with tool adapter numbers in programming