Siemens 840D 100650 - No NC/PLC found! NC/PLC being simulated!

No NC/PLC found! NC/PLC being simulated!

Siemens SINUMERIK alarm 100650: No NC/PLC found! NC/PLC being simulated!. This alarm indicates a required configuration element, parameter, or program component is missing or has not been set up.

Root Cause Summary

SINUMERIK alarm 100650 indicates the NCK (Numerical Control Kernel) and/or PLC cannot be found or properly initialized, forcing the system into simulation mode. This typically occurs during system startup when hardware communication fails or when running in virtual/simulation environments.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check NCK Power Supply

    Verify 24VDC power supply to NCK module and check LED status indicators on NCK unit for proper operation.

    Ensure proper lockout/tagout procedures before checking electrical connections.

  2. 2

    Verify DRIVE-CLiQ Communication

    Check DRIVE-CLiQ cable connections between NCU and NCK, inspect for damaged cables or loose connections at X101/X102 interfaces.

    Use STARTER software to diagnose DRIVE-CLiQ topology and communication status.

  3. 3

    Check NCK Module Status

    Access HMI Diagnostics > Hardware > NCK to verify module recognition and status in SINUMERIK system configuration.

    Compare detected hardware with configured hardware in machine data MD10000 (NCK_MM_SYSTEM_CONFIG).

  4. 4

    Perform NCK Reset

    Execute NCK cold restart via HMI Commissioning > System > NCK > Reset NCK or power cycle the complete system.

    Save all programs and data before performing NCK reset as unsaved changes will be lost.

DIY Feasiblehigh confidence

Call a technician if:

  • ·NCK hardware module replacement needed
  • ·Complete software reinstallation required
  • ·DRIVE-CLiQ topology errors persist
  • ·Safety system integration issues

Prevention

  • Regular system backups including NCK and PLC programs
  • Monitor DRIVE-CLiQ cable condition during preventive maintenance
  • Keep system software versions synchronized during updates
  • Document hardware configuration changes in machine data

Common Mistakes

  • Disabling simulation mode without verifying hardware connection
  • Performing NCK reset without backing up programs
  • Ignoring DRIVE-CLiQ communication errors
  • Mixing incompatible software versions during updates