Siemens 840D 100650 - No NC/PLC found! NC/PLC being simulated!
SINUMERIK alarm 100650 indicates the NCK (Numerical Control Kernel) and/or PLC cannot be found or properly initialized, forcing the system into simulation mode. This typically occurs during system startup when hardware communication fails or when running in virtual/simulation environments.
Siemens 840D 100650 - No NC/PLC found! NC/PLC being simulated!
No NC/PLC found! NC/PLC being simulated!
Siemens SINUMERIK alarm 100650: No NC/PLC found! NC/PLC being simulated!. This alarm indicates a required configuration element, parameter, or program component is missing or has not been set up.
Root Cause Summary
SINUMERIK alarm 100650 indicates the NCK (Numerical Control Kernel) and/or PLC cannot be found or properly initialized, forcing the system into simulation mode. This typically occurs during system startup when hardware communication fails or when running in virtual/simulation environments.
Safety
Causes and Fixes
Check NCK Power Supply
Verify 24VDC power supply to NCK module and check LED status indicators on NCK unit for proper operation.
Ensure proper lockout/tagout procedures before checking electrical connections.
Verify DRIVE-CLiQ Communication
Check DRIVE-CLiQ cable connections between NCU and NCK, inspect for damaged cables or loose connections at X101/X102 interfaces.
Use STARTER software to diagnose DRIVE-CLiQ topology and communication status.
Check NCK Module Status
Access HMI Diagnostics > Hardware > NCK to verify module recognition and status in SINUMERIK system configuration.
Compare detected hardware with configured hardware in machine data MD10000 (NCK_MM_SYSTEM_CONFIG).
Perform NCK Reset
Execute NCK cold restart via HMI Commissioning > System > NCK > Reset NCK or power cycle the complete system.
Save all programs and data before performing NCK reset as unsaved changes will be lost.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.