Siemens SINUMERIK codes
Siemens SINUMERIKCommunicationIntermediate30-120 minutes

100652

Siemens 840D 100652 - Network driver error! (network connection correct?)

Network driver error! (network connection correct?)

Siemens SINUMERIK alarm 100652: Network driver error! (network connection correct?). This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

SIEMENS alarm 100652 indicates a communication failure between the NCU and servo drives via DRIVE-CLiQ or PROFIBUS network. This alarm typically occurs when the network driver cannot establish or maintain proper communication with the servo amplifiers, often due to physical connection issues, configuration mismatches, or network timing problems.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check DRIVE-CLiQ cable connections

    Verify all DRIVE-CLiQ cables are firmly seated in X100/X101 connectors on NCU and servo drives. Check for visible damage to cable shielding.

    Power down system before disconnecting DRIVE-CLiQ cables to prevent component damage.

  2. 2

    Inspect cable routing and strain relief

    Examine DRIVE-CLiQ cable routing for excessive bending, pinching, or mechanical stress. Ensure minimum bend radius of 10x cable diameter is maintained.

    DRIVE-CLiQ cables should not run parallel to power cables - maintain 10cm minimum separation.

  3. 3

    Test cable continuity

    Use multimeter to check continuity on DRIVE-CLiQ cable pairs. Replace cable if any conductor shows open circuit or intermittent connection.

    DRIVE-CLiQ uses differential signaling - test both conductors in each twisted pair.

DIY Feasiblehigh confidence

Call a technician if:

  • ·NCU hardware replacement required
  • ·Multiple drive failures
  • ·Persistent errors after cable and configuration verification

Prevention

  • Regular DRIVE-CLiQ cable inspection
  • Maintain proper cable routing and strain relief
  • Monitor 24VDC supply voltage stability
  • Keep PROFIBUS network load below 70%

Common Mistakes

  • Ignoring proper PROFIBUS termination
  • Using incorrect GSD files
  • Mixing DRIVE-CLiQ and PROFIBUS troubleshooting procedures
  • Not checking 24VDC supply under load conditions

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.