Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100565

Siemens 840D 100565 - Automatic test machine stopped

Automatic test machine stopped

Siemens SINUMERIK operator message 100565: Automatic test machine stopped. This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.

Root Cause Summary

SIEMENS alarm 100565 indicates the automatic test machine function has been stopped, typically occurring during servo axis commissioning or diagnostic routines. This alarm fires when the built-in servo test sequences are interrupted or fail to complete properly due to hardware issues, parameter conflicts, or safety interlocks.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check servo drive status

    Navigate to Diagnostics > Drive > Status and examine all servo axes for fault indicators or red status lights on drive modules.

    Ensure machine is in safe state before checking drive status

  2. 2

    Verify encoder feedback

    In HMI go to Diagnostics > Machine > Actual Values and confirm encoder position feedback is stable and updating correctly for all axes.

    Look for erratic position values or frozen encoder counts

  3. 3

    Check drive parameters

    Access Parameters > Machine Data > Drives and verify MD30xxx series parameters match motor nameplate data and encoder specifications.

    Pay special attention to MD30110 (motor type) and MD31050 (encoder type)

  4. 4

    Restart automatic test

    Clear all alarms, then restart test via Commissioning > Servo > Automatic Test Machine function after resolving hardware issues.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Hardware component replacement needed
  • ·Safety system modifications required
  • ·Complex parameter corruption

Prevention

  • Regular backup of machine data parameters
  • Periodic safety system testing
  • Monitor drive communication status
  • Keep servo drive firmware updated

Common Mistakes

  • Ignoring safety interlocks during testing
  • Not backing up parameters before changes
  • Overlooking bus communication errors
  • Running tests with incorrect axis parameters

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.