Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeBasic2-10 minutes

1010

Siemens 1010 - Channel system error action <ALNX>

Channel system error action <ALNX>

With this alarm, internal alarm states are displayed that, in conjunction with the transferred error number, provide information on the cause and location of the error Control reaction: NC not ready. Interpreter stop Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Root Cause Summary

SIEMENS alarm 1010 'Block Search Active' occurs when the SINUMERIK control is performing an extended block search operation that exceeds normal processing time. This typically happens during program restart, repositioning operations, or when searching through large NC programs with complex block structures.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Program Size

    Access HMI → Program Manager → Properties to view current NC program size and block count. Programs over 10MB or 50,000 blocks typically cause extended search times.

  2. 2

    Monitor Search Progress

    Observe the block search progress indicator in the Program area of the HMI. Allow sufficient time for completion - large programs may require 30-60 seconds.

    Press the Stop key only if search exceeds 2 minutes to avoid program corruption

  3. 3

    Optimize Program Structure

    Consider breaking large programs into smaller subroutines using CALL statements or implement program segmentation to reduce search overhead.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Block search consistently fails after 5+ minutes
  • ·NCK memory errors appear
  • ·Hardware storage failures detected

Prevention

  • Optimize NC program structure with smaller subroutines
  • Regularly monitor NCK performance metrics
  • Maintain adequate free memory in NCK
  • Use local storage for frequently accessed programs

Common Mistakes

  • Interrupting block search prematurely
  • Ignoring NCK memory allocation warnings
  • Running oversized programs without optimization
  • Not monitoring storage device health

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.