Siemens 840D 101000 - No connection to PLC !

No connection to PLC !

Siemens SINUMERIK alarm 101000: No connection to PLC!. This alarm indicates a required configuration element, parameter, or program component is missing or has not been set up.

Root Cause Summary

Alarm 101000 indicates the NCK (Numerical Control Kernel) cannot establish communication with the PLC during system startup. This is typically caused by incorrect PLC basic program versions, communication hardware failures, or configuration mismatches between NCK and PLC components.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check the PLC program name and version in HMI > Commissioning > PLC. Verify it matches the NCK software version requirements (consult SINUMERIK 840D documentation for compatibility matrix).

  2. 2

    Load the correct PLC basic program via SIMATIC Manager or from the Siemens commissioning package matching your NCK software version (typically found on PCU or CF card backup).

    Ensure you have a backup before overwriting the existing PLC program

  3. 3

    Transfer the PLC program to the PLC CPU, compile, and download. Verify no compilation errors exist in STEP 7.

  4. 4

    Perform a complete power cycle (NCU and PLC) and monitor the boot sequence. Check if alarm clears and communication is established.

    Wait at least 30 seconds after power-down before restarting

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.