Siemens 1004 - Alarm reaction to NCK alarm incorrectly configured

Alarm reaction to NCK alarm incorrectly configured

The alarm reaction configured by the operating system or the compile cycles manufacturer is incorrect Control reaction: NC not ready. Channel not ready. Interface signals are set. Alarm display.

Root Cause Summary

SINUMERIK alarm 1004 occurs when the NCK alarm reaction configuration contains invalid or incompatible settings in the machine data or safety configuration. This typically happens after parameter changes, software updates, or when alarm reaction parameters don't match the actual system hardware configuration.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Access NCK machine data

    Navigate to Commissioning > Machine data > NCK-specific MD > Channel-specific data and locate MD11600 series parameters.

    Always backup current MD settings before making changes

  2. 2

    Verify alarm reaction settings

    Check MD11600[n] values against the valid alarm reaction bit patterns in the SINUMERIK documentation. Common invalid combinations include conflicting STOP and CANCEL reactions.

    Incorrect alarm reactions can compromise machine safety

  3. 3

    Reset to default values

    Set MD11600 entries to manufacturer default values, then perform NCK reset with POWER ON to activate changes.

    Use HMI function 'Reset to default' for systematic restoration

  4. 4

    Validate configuration

    Trigger a test alarm condition to verify the alarm reaction behaves correctly without generating alarm 1004.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Safety system modifications required
  • ·Multiple concurrent NCK alarms
  • ·Hardware replacement needed

Prevention

  • Always backup machine data before modifications
  • Validate alarm reactions after any software updates
  • Document all safety configuration changes
  • Perform regular system configuration audits

Common Mistakes

  • Modifying safety parameters without proper authorization
  • Ignoring software migration requirements
  • Mixing alarm reaction formats from different software versions
  • Not synchronizing NCK reset after MD changes

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.