Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100363

Siemens 840D 100363 - Password has been changed, please confirm first

Password has been changed, please confirm first

Siemens SINUMERIK operator message 100363: Password has been changed, please confirm first. This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.

Root Cause Summary

SIEMENS alarm 100363 occurs when a servo drive password has been modified and requires user confirmation before the system can proceed with servo operations. This is a security feature in SINUMERIK systems to prevent unauthorized changes to critical servo parameters.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access servo diagnostics

    Navigate to Diagnostics > Hardware > Drives in the HMI to view current servo drive status and password requirements.

    Check the drive status display for any password-related indicators before proceeding.

  2. 2

    Confirm new password

    Go to Commissioning > Drive > Password and enter the new password twice to confirm the change. Use parameter P0010 to set the drive to commissioning mode if needed.

    Ensure you have the correct new password before attempting confirmation to avoid lockout.

  3. 3

    Reset drive communication

    Execute a drive reset using parameter P0970 = 1 or through HMI Diagnostics > Hardware > Drives > Reset to clear the password confirmation requirement.

    Monitor parameter r0002 (drive status word) to verify successful password acceptance.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Multiple failed password attempts causing drive lockout
  • ·Safety parameter changes required without proper authorization
  • ·Firmware corruption suspected

Prevention

  • Document all password changes in maintenance logs
  • Use parameter backup functions before making changes
  • Implement controlled access procedures for drive commissioning

Common Mistakes

  • Not confirming password changes properly
  • Using incorrect password levels for different parameter types
  • Forgetting to save parameters after password confirmation