Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100407

Siemens 840D 100407 - Error var. access: Format wrong

Error var. access: Format wrong

Siemens SINUMERIK alarm 100407: Error var. access: Format wrong. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

SIEMENS alarm 100407 indicates a format mismatch when accessing system variables, typically occurring when the data type or format specification doesn't match the expected variable format. This commonly happens during PLC variable access, HMI data exchange, or when using incorrect format specifiers in NC programs or system functions.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check PLC variable definitions

    Navigate to Commissioning → PLC → Variables and verify the data types of variables being accessed match the format used in NC program or HMI.

    Use PLCM address to verify exact variable format in Step7/TIA Portal

  2. 2

    Verify R-parameter assignments

    Check if R-parameters are correctly assigned to PLC variables using proper format specifiers (e.g., $A_DBB, $A_DBW, $A_DBD for different data widths).

    Incorrect data width access can cause memory corruption

  3. 3

    Validate variable access syntax

    Review NC program lines containing variable access and ensure format matches PLC variable definition (BOOL, BYTE, WORD, DWORD, REAL).

  4. 4

    Test with direct variable access

    Use Service → Variables to manually read/write the problematic variable and confirm data type compatibility.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Memory corruption persists after restoration
  • ·System variables remain inaccessible
  • ·Multiple variable types affected simultaneously

Prevention

  • Always verify variable data types before programming
  • Use consistent format specifiers across HMI and NC programs
  • Regular backup of variable configurations
  • Validate PLC-NCK interface definitions during commissioning

Common Mistakes

  • Mixing WORD and DWORD access for same variable
  • Using %d format for REAL variables
  • Incorrect array indexing for system variables
  • Not matching PLC DB structure with NCK variable definitions