Siemens 840D 100407 - Error var. access: Format wrong
SIEMENS alarm 100407 indicates a format mismatch when accessing system variables, typically occurring when the data type or format specification doesn't match the expected variable format. This commonly happens during PLC variable access, HMI data exchange, or when using incorrect format specifiers in NC programs or system functions.
Siemens 840D 100407 - Error var. access: Format wrong
Error var. access: Format wrong
Siemens SINUMERIK alarm 100407: Error var. access: Format wrong. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.
Root Cause Summary
SIEMENS alarm 100407 indicates a format mismatch when accessing system variables, typically occurring when the data type or format specification doesn't match the expected variable format. This commonly happens during PLC variable access, HMI data exchange, or when using incorrect format specifiers in NC programs or system functions.
Safety
Causes and Fixes
Check PLC variable definitions
Navigate to Commissioning → PLC → Variables and verify the data types of variables being accessed match the format used in NC program or HMI.
Use PLCM address to verify exact variable format in Step7/TIA Portal
Verify R-parameter assignments
Check if R-parameters are correctly assigned to PLC variables using proper format specifiers (e.g., $A_DBB, $A_DBW, $A_DBD for different data widths).
Incorrect data width access can cause memory corruption
Validate variable access syntax
Review NC program lines containing variable access and ensure format matches PLC variable definition (BOOL, BYTE, WORD, DWORD, REAL).
Test with direct variable access
Use Service → Variables to manually read/write the problematic variable and confirm data type compatibility.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.