Siemens SINUMERIK alarm 100402: Temporarily no access rights!. This alarm indicates a required configuration element, parameter, or program component is missing or has not been set up.

Root Cause Summary

SIEMENS alarm 100402 occurs when the SINUMERIK system temporarily denies access to specific functions, parameters, or system areas due to protection level restrictions, active safety states, or concurrent access conflicts. This alarm typically fires when attempting to access machine data, safety functions, or system parameters while the system is in a restricted operational state.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Current Protection Level

    Navigate to HMI → Diagnostics → Service → Protection and verify current protection level status. Check MD9100 $MN_PROTECTION_LEVEL setting.

    Protection level 7 provides full access, while levels 1-3 are highly restricted

  2. 2

    Enter Correct Password

    Access HMI → Startup → Protection → Password and enter the appropriate password for required protection level (Manufacturer, Service, User, or OEM level).

    Never share protection passwords with unauthorized personnel

  3. 3

    Verify Access Rights

    Check MD9101-9107 password definitions and ensure the protection level grants access to the specific function causing the alarm.

    Some functions require temporary elevation - the system automatically downgrades after timeout

DIY Feasiblehigh confidence

Call a technician if:

  • ·Safety system malfunction
  • ·Corrupted user management
  • ·Hardware authentication failure

Prevention

  • Implement proper user training on protection levels
  • Establish clear procedures for safety acknowledgment
  • Regular backup of user management settings
  • Monitor concurrent system access

Common Mistakes

  • Attempting to bypass safety functions
  • Using maximum protection level for routine operations
  • Not waiting for system initialization completion
  • Multiple users accessing same parameters simultaneously

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.