Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100403

Siemens 840D 100403 - No access rights!

No access rights!

Siemens SINUMERIK alarm 100403: No access rights!. This alarm indicates a required configuration element, parameter, or program component is missing or has not been set up.

Root Cause Summary

SIEMENS alarm 100403 'No access rights %1!' occurs when the current user level lacks sufficient authorization to access specific SINUMERIK functions, parameters, or system areas. This is typically related to password protection levels or user privilege restrictions in the HMI system.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Current Access Level

    Navigate to HMI → Diagnostics → Service → General → Access authorization to view current user level and required level for the function.

    The %1 parameter in the alarm message indicates which specific function or area requires higher access

  2. 2

    Enter Appropriate Password

    Press 'Login' softkey and enter the correct password for required access level. Service level typically requires machine manufacturer password.

    Never share service or manufacturer passwords with unauthorized personnel

  3. 3

    Verify Access Rights

    After successful login, attempt the original function again. Check that the access level indicator shows the appropriate level (2 or 3).

DIY Feasiblehigh confidence

Call a technician if:

  • ·Unknown or forgotten passwords
  • ·Safety system modifications required
  • ·User management system corruption

Prevention

  • Document all password levels and store securely
  • Train operators on proper access level requirements
  • Regular backup of user management settings
  • Implement proper user role definitions

Common Mistakes

  • Attempting to modify safety parameters without proper training
  • Using operator level access for service functions
  • Sharing high-level passwords inappropriately
  • Not checking current access level before parameter changes

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.