Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100361

Siemens 840D 100361 - Error on saving logic drive data

Error on saving logic drive data

Siemens SINUMERIK alarm 100361: Error on saving logic drive data. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

SIEMENS alarm 100361 occurs when the SINUMERIK system cannot save logic drive data to the NCK memory or hard disk. This typically happens during parameter changes, drive commissioning, or when the system attempts to store modified drive configuration data permanently.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check NCK memory status

    Navigate to HMI > Diagnostics > NCK > Memory and check available memory space. Look for memory utilization above 90%.

    Use MD18210 $MN_MM_NUM_FILES_MAX to check maximum file limit

  2. 2

    Clear unnecessary files

    Delete old part programs, unused subroutines, and temporary files via HMI > Program Manager. Remove files from _N_DEF_DIR and _N_SPF_DIR if not needed.

    Always backup critical programs before deletion

  3. 3

    Perform memory defragmentation

    Execute NCK reset with memory reorganization via HMI > Startup > NCK > Reset NCK with 'Reorganize memory' option selected.

    This process can take 10-15 minutes depending on memory size

  4. 4

    Verify drive data save

    Attempt to save drive parameters again through HMI > Commissioning > Drive > Save to NCK and monitor for alarm clearance.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Hard disk hardware failure confirmed
  • ·Multiple parameter consistency errors persist
  • ·Drive communication cannot be restored

Prevention

  • Regularly monitor NCK memory usage
  • Complete drive commissioning properly
  • Maintain adequate disk space
  • Backup drive parameters monthly

Common Mistakes

  • Interrupting parameter save process
  • Ignoring memory warnings
  • Modifying parameters without proper commissioning mode
  • Not verifying parameter consistency before saving

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.