100351

Siemens 840D 100351 - Display MD cannot be accepted

Display MD cannot be accepted

Siemens SINUMERIK alarm 100351: Display MD cannot be accepted. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

SIEMENS alarm 100351 occurs when the NCK rejects display machine data modifications due to access restrictions, data validation failures, or system state conflicts. This typically happens when attempting to save protected parameters or when the system is in an incompatible operating mode.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Current Protection Level

    Navigate to Diagnostics > Service > Protection Level and verify current access level. Display MDs typically require protection level 2 (SIEMENS) or higher.

    Use password 'SUNRISE' for protection level 2 access on most SINUMERIK systems

  2. 2

    Verify MD Protection Status

    In Commissioning > Machine Data, locate the specific display MD and check its protection level indicator. Look for lock symbols or protection level numbers.

    Never attempt to bypass protection levels without proper authorization

  3. 3

    Access with Proper Authorization

    Enter correct password for required protection level via Settings > Protection Level, then retry the MD modification.

    Protection level changes are logged in the system logbook for audit purposes

DIY Feasiblehigh confidence

Call a technician if:

  • ·Hardware display interface failures
  • ·Persistent MD corruption after multiple attempts
  • ·System-wide display subsystem malfunction

Prevention

  • Always verify protection levels before MD modifications
  • Document display configuration changes
  • Perform MD backups before major display updates
  • Validate hardware compatibility before parameter changes

Common Mistakes

  • Attempting MD changes during program execution
  • Using incorrect protection level passwords
  • Ignoring data type requirements
  • Not checking hardware display capabilities