Okuma OSP Alarm A 8511 - B-axis clamp/unclamp interlock
On a Macturn machine, a B-axis clamp command was issued while the B-axis was stopped at an angle other than 0, 90, 180 or 270 degrees, or a B-axis clamp/unclamp (M404/M403) was commanded while the turret was at the ATC index position. The clamp can only engage at the valid index angles, so the command is rejected to protect the clamp mechanism.
Okuma OSP Alarm A 8511 - B-axis clamp/unclamp interlock
B-axis clamp/unclamp interlock
On a Macturn machine, a B-axis clamp command was issued while the B-axis was stopped at an angle other than 0, 90, 180 or 270 degrees, or a B-axis clamp/unclamp (M404/M403) was commanded while the turret was at the ATC index position. The clamp can only engage at the valid index angles, so the command is rejected to protect the clamp mechanism.