Okuma OSP Controller
Power Supply · Intermediate
Okuma OSP Alarm C 3794 - Power source unit overload
The breaker feeding the lighting circuit inside the EC power unit has tripped. The control reports this as a power source unit overload because the lighting load is drawing more current than the breaker allows, usually from a shorted or grounded light cable.
Okuma OSP Alarm C 3794 - Power source unit overload
Power source unit overload
The breaker feeding the lighting circuit inside the EC power unit has tripped. The control reports this as a power source unit overload because the lighting load is drawing more current than the breaker allows, usually from a shorted or grounded light cable.
Common Causes
Troubleshooting Steps