Okuma OSP Alarm A 1829 - Sp. oil air lub. air pressure error

Sp. oil air lub. air pressure error

The control detected that air pressure feeding the spindle oil-air lubrication system dropped too low and stayed low for more than 30 seconds while air was being output. Without this air supply the spindle bearings lose their oil-air mist lubrication, so the control stops to protect the spindle.

Common Causes

  • Faulty air pump or leak/blockage in the air piping to the oil-air unit
  • Defective air pressure switch not confirming pressure
  • Damaged, kinked, or leaking oil-air plumbing lines
  • Failed oil-air pressure switch (PS) itself

Troubleshooting Steps

  1. 1Check the shop air supply and the oil-air unit's air pump: confirm air is actually reaching the unit and listen/feel for leaks along the piping.
  2. 2Inspect the oil-air plumbing lines for kinks, cracks, loose fittings, or oil-soaked spots indicating a leak; repair or replace damaged sections.
  3. 3Verify the air pressure switch changes state when pressure is applied and released; if it stays in one state, replace the pressure switch.
  4. 4If the plumbing and switch check out, replace the air unit with a new one.
  5. 5If the alarm persists, replace the oil-air pressure PS (pressure switch) and re-test.
  6. 6If it returns after these checks, record the alarm number and contact Okuma service.

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.