axismd.ai
Okuma OSP Controller
Tool Changer · Intermediate
Okuma OSP Alarm A 1779 - Manual tool change operation interlock
The M70 manual tool change command was issued while the turret was not indexed to a position where manual tool change is allowed, or the turret was indexed away from that position while M70 was still executing. On LB15II/LB35II-MATC-Y and LU45-MATC-Y machines, manual change is only possible with T1 at the cutting position or other stations at the ATC position.
Okuma OSP Alarm A 1779 - Manual tool change operation interlock
Manual tool change operation interlock
The M70 manual tool change command was issued while the turret was not indexed to a position where manual tool change is allowed, or the turret was indexed away from that position while M70 was still executing. On LB15II/LB35II-MATC-Y and LU45-MATC-Y machines, manual change is only possible with T1 at the cutting position or other stations at the ATC position.
Common Causes
Troubleshooting Steps
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.