Okuma OSP Alarm A 1752 - Tow-along tailstock clamp/unclamp error
The control lost a valid clamp/unclamp (connection ON/OFF) confirmation from the tow-along tailstock: neither signal, both signals at once, or the connection ON signal appearing when the X-axis is not at stroke end or the tailstock spindle is not retracted. The tailstock connect state is therefore unreliable and axis movement is blocked to prevent towing an unclamped tailstock.
Okuma OSP Alarm A 1752 - Tow-along tailstock clamp/unclamp error
Tow-along tailstock clamp/unclamp error
The control lost a valid clamp/unclamp (connection ON/OFF) confirmation from the tow-along tailstock: neither signal, both signals at once, or the connection ON signal appearing when the X-axis is not at stroke end or the tailstock spindle is not retracted. The tailstock connect state is therefore unreliable and axis movement is blocked to prevent towing an unclamped tailstock.
Common Causes
Troubleshooting Steps
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?