Heidenhain codes
HeidenhainCommunicationIntermediate30-120 minutes

126-011C

HEIDENHAIN 126-011C - No reaction during self-test on with HSCI address

No reaction during self-test on with HSCI address

This TNC7/TNC 640 error (126-011C) relates to 'No reaction during self-test on with HSCI address '. During the device self-test, an expected message was not received.

Root Cause Summary

This alarm occurs when an HSCI bus component does not complete the mandatory communication handshake during the TNC control's power-up self-test sequence. The root cause is typically a physical connection problem, power supply issue, or failed HSCI component at the specific address shown in the alarm. The control cannot proceed with normal operation until all configured HSCI devices respond properly during initialization.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Power down and inspect HSCI cables

    Turn off main power. Disconnect and inspect the HSCI cable at both the TNC control's HSCI port and the component at address %3. Check for bent pins, cable damage, and proper shield grounding to the connector housings.

    Always disconnect main power before disconnecting HSCI cables to prevent damage to components.

  2. 2

    Verify cable continuity and shielding

    Use a multimeter to check continuity on all HSCI cable conductors. Verify shield continuity is less than 1 ohm to ground at both ends. Replace cable if any conductor shows open circuit or intermittent connection.

    HSCI cables should never exceed 20 meters total bus length without repeaters. Excessive length can cause self-test timeouts.

  3. 3

    Reconnect with proper torque

    Reconnect HSCI cable connectors ensuring they seat fully with audible click. Tighten connector screws to 0.4-0.5 Nm torque specification. Ensure cable routing avoids sharp bends (minimum 10x cable diameter bend radius).

  4. 4

    Power up and verify alarm clears

    Restore main power and observe startup sequence. If alarm persists, check PLC program log in Test Mode to see if component now responds partially, indicating intermittent connection issue.

DIY Feasiblemedium confidence

Call a technician if:

  • ·TNC HSCI interface hardware failure suspected
  • ·Multiple devices failing simultaneously
  • ·Firmware update required

Prevention

  • Regular HSCI cable inspection and replacement
  • Maintain proper cable routing away from interference sources
  • Keep HSCI termination resistors properly installed

Common Mistakes

  • Forgetting to install termination resistors
  • Using incorrect cable impedance
  • Not updating machine parameters after device changes